★Mark us as a preferred sourceSouth Korea’s National Fire Research Institute (NFRI) has tested in the laboratory how end-of-life cylindrical battery cells behave when exposed to external heat. The result carries a clear message for the waste sector: lithium-ion battery thermal runaway can occur even in cells that have reached the end of their service life, as long as enough electrical energy remains inside them. The institute published its findings on 11 November 2026.
In short: According to an experiment by Korea’s National Fire Research Institute, lithium-ion battery thermal runaway can develop in spent cells that still hold a residual charge. Waste 18650 cells with an average residual voltage of 3.94 V or higher went into thermal runaway with flames when heated externally, while cells at 3.45 V released gas and leaked electrolyte. The institute will use the results to train staff at collection, storage and recycling facilities.
Why did the Korean fire research institute launch the study?
The institute, which operates under South Korea’s National Fire Agency, started from the premise that waste lithium-ion batteries may still contain electrical energy after use. Fire risk therefore has to be considered at every stage of collection, storage and recycling.
The risk is far from theoretical in Korea. In January 2024, a fire broke out during the shredding of lithium waste batteries at a battery recycling company in Pyeongtaek, Gyeonggi Province. In April 2020, a fire that started during battery dismantling at a waste battery processing plant in Goryeong, North Gyeongsang Province, escalated into a chain of explosions and proved difficult to extinguish.
As lithium-ion batteries spread, the safe collection, storage and recycling of spent cells is becoming ever more important. The situation in Europe is similar: in Austria, there are now on average eight lithium batteries in every tonne of residual waste, and a growing share of fires at waste facilities can be traced back to them. The Korean researchers set out to determine experimentally how the onset of thermal runaway depends on residual voltage, and to gather baseline data for fire prevention at handling facilities.
How was the experiment carried out?
The researchers used collected waste lithium-ion cells of the cylindrical 18650 type – a format common in laptop batteries, power tool packs and the battery packs of e-bikes and e-scooters. The cells were grouped by residual voltage and then subjected to a thermal abuse test: they were heated externally at a constant rate.
Four characteristics were measured and observed:
- the change in cell temperature over time,
- whether gas venting and flames occurred,
- how thermal runaway developed,
- and, in the event of fire, the heat release rate.
The results were compared across the voltage groups. The press release did not disclose the number of cells tested or the exact heating rate.
Lithium-ion battery thermal runaway above 3.94 volts: what did the measurements show?
The waste cells exposed to external heat reacted differently depending on their average residual voltage.
In the group with an average residual voltage of 3.45 V, no thermal runaway occurred: the researchers observed only off-gassing and electrolyte leakage. Cells at 3.94 V or higher behaved very differently: their temperature rose sharply, and lithium-ion battery thermal runaway accompanied by flames followed.
According to the institute, this demonstrates that a battery taken out of use can still catch fire if electrical energy remains inside and it is exposed to external heat. Equally important is the second finding: gas release and electrolyte leakage also occurred in the group that did not go into thermal runaway. Safety rules for collection and storage must therefore account for both the energy remaining in the cells and the heat sources around them.
Why is a “dead” battery still dangerous?
Editor’s note: 18650 lithium-ion cells typically have a nominal voltage of 3.6–3.7 V and reach roughly 4.2 V when fully charged. It follows that the cells that caught fire in the experiment – at 3.94 V or above – still held a substantial charge, even though they arrived at the lab as “waste”.
In practice this is not unusual at all. A device is usually thrown away not because its battery is completely empty, but because it broke, became obsolete or was replaced. A discarded laptop, e-scooter or cordless tool may therefore contain cells that are almost fully charged. Moreover, a device’s electronics shut it down long before the cell is truly depleted – a “battery empty” warning does not mean a safe state.
Nor should the 3.45 V result be read as a safety threshold. The experiment used defined, constant external heating; the mechanical damage typical of waste handling – crushing, puncturing, shredding – creates different conditions, and the gases and electrolyte released in that state still pose a risk.
Lessons for waste management facilities
The Korean institute plans to use the experiment videos and test results in safety training and information materials for staff at facilities that collect, store and recycle waste lithium-ion batteries. Kim Yeon-sang, head of the institute, said the research experimentally confirmed that residual electrical energy combined with external heat creates a fire risk even in spent batteries, and that the institute will share related materials to support fire prevention and safety awareness on site.
The findings affect the entire battery recycling chain. Shredding and pre-treatment plants – which also produce black mass – work with exactly the kind of risks that led to fires in Pyeongtaek and Goryeong. Based on the Korean measurements, storage areas should pay particular attention to keeping cells away from heat sources, limiting stored quantities, segregating damaged or swollen batteries, and continuously monitoring gas emissions and temperature.
The issue is high on Europe’s agenda too: in Germany, waste industry associations are calling for stronger measures against waste management fires and for producers to share the financial burden. The Korean experiment provides clear, measurable laboratory evidence to support that debate.
What can households do?
Many fires at waste facilities are effectively decided in the home – by where a battery ends up. The key rules:
- Never in mixed or recycling bins: lithium-ion batteries and battery-powered devices belong at battery collection points, civic amenity sites (recycling yards) or retailer take-back points.
- Watch out for hidden batteries: anything that lights up, flashes, makes a sound or can be recharged almost certainly contains a power source – we covered this in our article on hidden lithium battery fire hazards.
- Tape the terminals: before dropping batteries off, cover exposed contacts with tape to prevent short circuits.
- Keep them away from heat: do not store spent – and especially damaged or swollen – batteries near radiators, sunny windowsills or other heat sources, and do not try to keep charging them.
The key takeaway from the Korean experiment is simple: becoming waste does not drain a battery of its energy.
FAQ: lithium-ion battery thermal runaway in waste batteries
Can lithium-ion battery thermal runaway occur in a spent battery?
Yes, if the cell still holds significant electrical energy. In the experiment by South Korea’s National Fire Research Institute, waste 18650 cells with an average residual voltage of 3.94 V or higher went into thermal runaway with flames when exposed to external heat. “Spent” therefore does not mean that a battery is free of energy or safe.
What happened to the cells with lower residual voltage in the experiment?
Cells with an average residual voltage of 3.45 V did not go into thermal runaway, but they released gas and leaked electrolyte. According to the researchers, this shows that both the remaining energy and nearby heat sources must be considered when collecting and storing waste batteries, as the released gases and electrolyte pose risks in their own right.
How did the Korean research institute carry out the experiment?
Collected cylindrical 18650 waste lithium-ion cells were grouped by residual voltage and then heated externally at a constant rate. The researchers measured cell temperature over time, gas venting and flame formation, how thermal runaway developed and, in the event of fire, the heat release rate, then compared the results across the voltage groups.
What can households do to prevent fires caused by waste batteries?
Most importantly, lithium-ion batteries and battery-powered devices should never go into mixed waste or recycling bins. Take them to a battery collection point, civic amenity site or retailer take-back point, cover exposed terminals with tape beforehand, and store damaged or swollen cells away from heat sources until they can be dropped off.